BACnet Name |
BACnet Type |
ID |
Access |
COV |
Description |
|---|---|---|---|---|---|
|
UI-1 |
Analog Input |
0 |
Read-only |
Yes |
Universal input current value |
|
UI-2 |
Analog Input |
1 |
Read-only |
Yes |
|
|
UI-3 |
Analog Input |
2 |
Read-only |
Yes |
|
|
UI-4 |
Analog Input |
3 |
Read-only |
Yes |
|
|
UI-5 |
Analog Input |
4 |
Read-only |
Yes |
|
|
UI-6 |
Analog Input |
5 |
Read-only |
Yes |
|
|
UI-7 |
Analog Input |
6 |
Read-only |
Yes |
|
|
UI-8 |
Analog Input |
7 |
Read-only |
Yes |
|
|
AO-1 |
Analog Output |
0 |
Read/write |
Yes |
Analog output current value
|
|
AO-2 |
Analog Output |
1 |
Read/write |
Yes |
|
|
AO-3 |
Analog Output |
2 |
Read/write |
Yes |
|
|
AO-4 |
Analog Output |
3 |
Read/write |
Yes |
|
|
AO-5 |
Analog Output |
4 |
Read/write |
Yes |
|
|
AO-6 |
Analog Output |
5 |
Read/write |
Yes |
|
|
BI-1 |
Binary Input |
0 |
Read-only |
Yes |
Digital input current value
|
|
BI-2 |
Binary Input |
1 |
Read-only |
Yes |
|
|
BI-3 |
Binary Input |
2 |
Read-only |
Yes |
|
|
BI-4 |
Binary Input |
3 |
Read-only |
Yes |
|
|
BI-5 |
Binary Input |
4 |
Read-only |
Yes |
|
|
BI-6 |
Binary Input |
5 |
Read-only |
Yes |
|
|
BI-7 |
Binary Input |
6 |
Read-only |
Yes |
|
|
BI-8 |
Binary Input |
7 |
Read-only |
Yes |
|
|
BI-9 |
Binary Input |
8 |
Read-only |
Yes |
|
|
BI-10 |
Binary Input |
9 |
Read-only |
Yes |
|
|
BI-11 |
Binary Input |
10 |
Read-only |
Yes |
|
|
BI-12 |
Binary Input |
11 |
Read-only |
Yes |
|
|
BO-1 |
Binary Output |
0 |
Read/write |
Yes |
Digital output current value
|
|
BO-2 |
Binary Output |
1 |
Read/write |
Yes |
|
|
BO-3 |
Binary Output |
2 |
Read/write |
Yes |
|
|
BO-4 |
Binary Output |
3 |
Read/write |
Yes |
|
|
BO-5 |
Binary Output |
4 |
Read/write |
Yes |
|
|
BO-6 |
Binary Output |
5 |
Read/write |
Yes |
|
|
BO-7 |
Binary Output |
6 |
Read/write |
Yes |
|
|
BO-8 |
Binary Output |
7 |
Read/write |
Yes |
|
|
BO-9 |
Binary Output |
8 |
Read/write |
Yes |
|
|
BO-10 |
Binary Output |
9 |
Read/write |
Yes |
|
|
BO-11 |
Binary Output |
10 |
Read/write |
Yes |
|
|
BO-12 |
Binary Output |
11 |
Read/write |
Yes |
|
|
UI-1_DRY_ CONTACT |
Binary Value |
0 |
Read-only |
No |
Universal input dry contact binary value |
|
UI-2_DRY_ CONTACT |
Binary Value |
1 |
Read-only |
No |
|
|
UI-3_DRY_ CONTACT |
Binary Value |
2 |
Read-only |
No |
|
|
UI-4_DRY_ CONTACT |
Binary Value |
3 |
Read-only |
No |
|
|
UI-5_DRY_ CONTACT |
Binary Value |
4 |
Read-only |
No |
|
|
UI-6_DRY_ CONTACT |
Binary Value |
5 |
Read-only |
No |
|
|
UI-7_DRY_ CONTACT |
Binary Value |
6 |
Read-only |
No |
|
|
UI-8_DRY_ CONTACT |
Binary Value |
7 |
Read-only |
No |
|
|
UP_TIME |
Analog Value |
0 |
Read-only |
No |
Module working time [s] |
|
WATCHDOG |
Analog Value |
1 |
Read/write |
No |
Watchdog time value [s]
|
|
BI-1_COUNTER |
Analog Value |
2 |
Read/write |
No |
Digital input counter value
|
|
BI-2_COUNTER |
Analog Value |
3 |
Read/write |
No |
|
|
BI-3_COUNTER |
Analog Value |
4 |
Read/write |
No |
|
|
BI-4_COUNTER |
Analog Value |
5 |
Read/write |
No |
|
|
BI-5_COUNTER |
Analog Value |
6 |
Read/write |
No |
|
|
BI-6_COUNTER |
Analog Value |
7 |
Read/write |
No |
|
|
BI-7_COUNTER |
Analog Value |
8 |
Read/write |
No |
|
|
BI-8_COUNTER |
Analog Value |
9 |
Read/write |
No |
|
|
BI-9_COUNTER |
Analog Value |
10 |
Read/write |
No |
|
|
BI-10_COUNTER |
Analog Value |
11 |
Read/write |
No |
|
|
BI-11_COUNTER |
Analog Value |
12 |
Read/write |
No |
|
|
BI-12_COUNTER |
Analog Value |
13 |
Read/write |
No |
|
|
UI-1_FILTER |
Analog Value |
14 |
Read/write |
No |
Universal input low pass filter time value
|
|
UI-2_FILTER |
Analog Value |
15 |
Read/write |
No |
|
|
UI-3_FILTER |
Analog Value |
16 |
Read/write |
No |
|
|
UI-4_FILTER |
Analog Value |
17 |
Read/write |
No |
|
|
UI-5_FILTER |
Analog Value |
18 |
Read/write |
No |
|
|
UI-6_FILTER |
Analog Value |
19 |
Read/write |
No |
|
|
UI-7_FILTER |
Analog Value |
20 |
Read/write |
No |
|
|
UI-8_FILTER |
Analog Value |
21 |
Read/write |
No |
|
|
AO-1_HAND_VALE |
Analog Value |
22 |
Read-only |
No |
Analog output value in hand mode value
|
|
AO-2_HAND_VALE |
Analog Value |
23 |
Read-only |
No |
|
|
AO-3_HAND_VALE |
Analog Value |
24 |
Read-only |
No |
|
|
AO-4_HAND_VALE |
Analog Value |
25 |
Read-only |
No |
|
|
UI-1_CONFIGURATION |
Multistate Value |
1 |
Read/write |
No |
Universal input configuration:
|
|
UI-2_CONFIGURATION |
Multistate Value |
2 |
Read/write |
No |
|
|
UI-3_CONFIGURATION |
Multistate Value |
3 |
Read/write |
No |
|
|
UI-4_CONFIGURATION |
Multistate Value |
4 |
Read/write |
No |
|
|
UI-5_CONFIGURATION |
Multistate Value |
5 |
Read/write |
No |
|
|
UI-6_CONFIGURATION |
Multistate Value |
6 |
Read/write |
No |
|
|
UI-7_CONFIGURATION |
Multistate Value |
7 |
Read/write |
No |
|
|
UI-8_CONFIGURATION |
Multistate Value |
8 |
Read/write |
No |
|
|
UI-1_RESOLUTION |
Multistate Value |
9 |
Read/write |
No |
Universal input resolution:
|
|
UI-2_RESOLUTION |
Multistate Value |
10 |
Read/write |
No |
|
|
UI-3_RESOLUTION |
Multistate Value |
11 |
Read/write |
No |
|
|
UI-4_RESOLUTION |
Multistate Value |
12 |
Read/write |
No |
|
|
UI-5_RESOLUTION |
Multistate Value |
13 |
Read/write |
No |
|
|
UI-6_RESOLUTION |
Multistate Value |
14 |
Read/write |
No |
|
|
UI-7_RESOLUTION |
Multistate Value |
15 |
Read/write |
No |
|
|
UI-8_RESOLUTION |
Multistate Value |
16 |
Read/write |
No |
|
|
AO-1_CONFIGURATION |
Multistate Value |
17 |
Read/write |
No |
Analog output working mode
|
|
AO-2_CONFIGURATION |
Multistate Value |
18 |
Read/write |
No |
|
|
AO-3_CONFIGURATION |
Multistate Value |
19 |
Read/write |
No |
|
|
AO-4_CONFIGURATION |
Multistate Value |
20 |
Read/write |
No |
|
|
AO-5_CONFIGURATION |
Multistate Value |
21 |
Read/write |
No |
|
|
AO-6_CONFIGURATION |
Multistate Value |
22 |
Read/write |
No |
|
|
AO-1_HAND_STATUS |
Multistate Value |
23 |
Read-only |
No |
Analog output value in hand mode status: hand/auto
|
|
AO-2_HAND_STATUS |
Multistate Value |
24 |
Read-only |
No |
|
|
AO-3_HAND_STATUS |
Multistate Value |
25 |
Read-only |
No |
|
|
AO-4_HAND_STATUS |
Multistate Value |
26 |
Read-only |
No |
|
|
BO-1_HAND_STATUS |
Multistate Value |
23 |
Read-only |
No |
Digital output value in hand mode status: hand/auto
|
|
BO-2_HAND_STATUS |
Multistate Value |
24 |
Read-only |
No |
|
|
BO-3_HAND_STATUS |
Multistate Value |
25 |
Read-only |
No |
|
|
BO-4_HAND_STATUS |
Multistate Value |
26 |
Read-only |
No |
|
|
BIA-1_COUNTER |
Accumulator |
0 |
Read/write |
No |
Digital input counter value
|
|
BIA-2_COUNTER |
Accumulator |
1 |
Read/write |
No |
|
|
BIA-3_COUNTER |
Accumulator |
2 |
Read/write |
No |
|
|
BIA-4_COUNTER |
Accumulator |
3 |
Read/write |
No |
|
|
BIA-5_COUNTER |
Accumulator |
4 |
Read/write |
No |
|
|
BIA-6_COUNTER |
Accumulator |
5 |
Read/write |
No |
|
|
BIA-7_COUNTER |
Accumulator |
6 |
Read/write |
No |
|
|
BIA-8_COUNTER |
Accumulator |
7 |
Read/write |
No |
|
|
BIA-9_COUNTER |
Accumulator |
8 |
Read/write |
No |
|
|
BIA-10_COUNTER |
Accumulator |
9 |
Read/write |
No |
|
|
BIA-11_COUNTER |
Accumulator |
10 |
Read/write |
No |
|
|
BIA-12_COUNTER |
Accumulator |
11 |
Read/write |
No |
|
|
For MINI 4TO-H and 4TO-H-IP only |
|||||
|
TO-1 |
Binary Output |
0 |
Read/write |
Yes |
Triac output current value (in digital output operation mode)
|
|
TO-2 |
Binary Output |
1 |
Read/write |
Yes |
|
|
TO-3 |
Binary Output |
2 |
Read/write |
Yes |
|
|
TO-4 |
Binary Output |
3 |
Read/write |
Yes |
|
|
TO-1_PWM VALUE |
Analog Output |
0 |
Read/write |
Yes |
Triac output current value (in PWM operation mode)
|
|
TO-2_PWM VALUE |
Analog Output |
1 |
Read/write |
Yes |
|
|
TO-3_PWM VALUE |
Analog Output |
2 |
Read/write |
Yes |
|
|
TO-4_PWM VALUE |
Analog Output |
3 |
Read/write |
Yes |
|
|
TO-1_CONFIGURATION |
Multistate Value |
17 |
Read/write |
No |
Triac output operation mode configuration, options:
|
|
TO-1_CONFIGURATION |
Multistate Value |
18 |
Read/write |
No |
|
|
TO-1_CONFIGURATION |
Multistate Value |
19 |
Read/write |
No |
|
|
TO-1_CONFIGURATION |
Multistate Value |
20 |
Read/write |
No |
|
|
TO-1_ HAND_STATUS |
Multistate Value |
23 |
Read-only |
No |
Triac output hand mode status
|
|
TO-1_ HAND_STATUS |
Multistate Value |
24 |
Read-only |
No |
|
|
TO-1_ HAND_STATUS |
Multistate Value |
25 |
Read-only |
No |
|
|
TO-1_ HAND_STATUS |
Multistate Value |
26 |
Read-only |
No |
|
|
For MINI 4I4O-H and 4I4O-H-IP only |
|||||
|
BI-1_INPUT_MODE |
Multistate Value |
27 |
Read/write |
No |
Ordinary IO (def) Monostable Relay Bistable Relay Time Relay NO [ms] Time Relay NC [ms] Time Relay NO [s] Time Relay NC [s] Input Forwarding (4U4O-H, 4U4O-H-IP only) Heating Cooling |
|
BI-2_INPUT_MODE |
Multistate Value |
28 |
Read/write |
No |
|
|
BI-3_INPUT_MODE |
Multistate Value |
29 |
Read/write |
No |
|
|
BI-4_INPUT_MODE |
Multistate Value |
30 |
Read/write |
No |
|
|
BI-1_MODE_TIME |
Analog Value |
26 |
Read/write |
No |
Time Value object for Time Relay Mode |
|
BI-2_MODE_TIME |
Analog Value |
27 |
Read/write |
No |
|
|
BI-3_MODE_TIME |
Analog Value |
28 |
Read/write |
No |
|
|
BI-4_MODE_TIME |
Analog Value |
29 |
Read/write |
No |
|
|
BI-1_BLOCK_INPUT |
Binary Value |
8 |
Read/write |
No |
Digital input blocking command
|
|
BI-2_BLOCK_INPUT |
Binary Value |
9 |
Read/write |
No |
|
|
BI-3_BLOCK_INPUT |
Binary Value |
10 |
Read/write |
No |
|
|
BI-4_BLOCK_INPUT |
Binary Value |
11 |
Read/write |
No |
|
|
BI-1_COMMAND |
Binary Value |
12 |
Read/write |
No |
Digital input remote command
|
|
BI-2_COMMAND |
Binary Value |
13 |
Read/write |
No |
|
|
BI-3_COMMAND |
Binary Value |
14 |
Read/write |
No |
|
|
BI-4_COMMAND |
Binary Value |
15 |
Read/write |
No |
|
|
For MINI 4U4O-H and 4U4O-H-IP only |
|||||
|
BI-1_SETPOINT |
Analog Value |
30 |
Read/write |
No |
SETPOINT for heating/cooling modes Default: 0
|
|
BI-2_SETPOINT |
Analog Value |
31 |
Read/write |
No |
|
|
BI-3_SETPOINT |
Analog Value |
32 |
Read/write |
No |
|
|
BI-4_SETPOINT |
Analog Value |
33 |
Read/write |
No |
|
|
BI-1_DIFFERENTIAL |
Analog Value |
34 |
Read/write |
No |
DIFFERENTIAL for heating/cooling modes Default: 0
|
|
BI-2_ DIFFERENTIAL |
Analog Value |
35 |
Read/write |
No |
|
|
BI-3_ DIFFERENTIAL |
Analog Value |
36 |
Read/write |
No |
|
|
BI-4_ DIFFERENTIAL |
Analog Value |
37 |
Read/write |
No |
|
List of BACnet objects