BACnet ID |
Object properties |
Object type |
Object name |
Access |
|
|---|---|---|---|---|---|
|
0 |
Mac Address |
Network port |
Module address |
Read only |
|
|
0 |
Present value |
Analog value |
UP TIME |
Read only |
|
|
0 |
Link speed |
Network port |
Baud rate |
Read/write |
|
|
120 |
Present value |
Analog value |
PRESSURE SENSOR RESOLUTION |
Read/write (only for EBV and MVE-2-RS with Custom Energy Valve) |
|
|
9 |
Present value |
Multi state value |
MAX. FLOW SETTING |
Read/write (only for MVE/MVC-2-RS) |
|
|
VLX1-5 VLX1P-5P |
VLXHF VLX.PHF |
||||
|
1 |
1 |
||||
|
1,25 |
2 |
||||
|
1,5 |
3 |
||||
|
1,75 |
4 |
||||
|
2 |
5 |
||||
|
2,25 |
6 |
||||
|
2,5 |
7 |
||||
|
2,75 |
8 |
||||
|
3 |
9 |
||||
|
3,25 |
10 |
||||
|
3,5 |
/ |
||||
|
3,75 |
/ |
||||
|
4 |
/ |
||||
|
4,25 |
/ |
||||
|
4,5 |
/ |
||||
|
4,75 |
/ |
||||
|
5 |
/ |
||||
|
0 |
Present value |
Multi state value |
TYPE OF CONTROL |
Read/write |
|
|
Modbus/BACnet |
|||||
|
0-10V |
|||||
|
2-10V |
|||||
|
0-5V (only for EBV/MVE-2-RS) |
|||||
|
5-10V (only for EBV/MVE-2-RS) |
|||||
|
2-6V (only for EBV/MVE-2-RS) |
|||||
|
6-10V (only for EBV/MVE-2-RS) |
|||||
|
Selected by dip |
|||||
|
0 |
Present value |
Binary value |
DIRECT/REVERSE ACTION |
Read/write |
|
|
1 |
FAILSAFE DIRECTION |
||||
|
15 |
TYPE OF STROKE (only for MVC-2-RS) |
||||
|
2 |
Present value |
Binary value |
ENABLE CALIBRATION |
Read/write |
|
|
3 |
Present value |
Binary value |
JUMPER ENABLE (ER BOARD) |
Read/write (it’s visible only for EBV/MVE-2-RS) |
|
|
1 |
Present value |
Multi state value |
CHANGEOVER SETTING |
Read/write |
|
|
Heating |
|||||
|
Cooling |
|||||
|
Automatic (depends on delta T) |
|||||
|
2 |
Present value |
Multi state value |
TEMPERATURE SENSOR SELECTION |
Read/write |
|
|
T1 (supply) |
|||||
|
T2 (return) |
|||||
|
T1, T2 (delta T) |
|||||
|
10 |
Present value |
Multi state value |
ACTUATOR SPEED |
Read/write (MVC-2-RS only) |
|
|
5s/mm |
|||||
|
3s/mm |
|||||
|
3 |
Present value |
Multi state value |
VALVE CHARACTERISTICS CONFIGURATION: |
Read/write |
|
|
Linear |
|||||
|
Equipercentage |
|||||
|
4 |
Present value |
Multi state value |
FUNCTIONS ENABLE: |
Read/write |
|
|
BMS |
|||||
|
Temperature control |
|||||
|
Temperature ΔT limit |
|||||
|
Temperature max limit |
|||||
|
Temperature min limit |
|||||
|
Power control |
|||||
|
Power limit |
|||||
|
14 |
Present value |
Binary value |
FUNCTIONS ENABLE (ENERGY) |
Read/write |
|
|
5 |
Present value |
Multi state value |
Functions status |
Read only |
|
|
1 |
Present value |
Analog value |
MINIMUM OPENING VALVE |
Read/write |
|
|
2 |
Present value |
Analog value |
DIP SWITCH SETTING |
Read only |
|
|
6 |
Present value |
Multi state value |
VALVE TYPE: |
Read/write (the visible options depend on the connected actuator) |
|
|
Generic |
|||||
|
Reserved |
|||||
|
Reserved |
|||||
|
Reserved |
|||||
|
Custom energy valve |
|||||
|
VLX6P |
|||||
|
VLX8P |
|||||
|
VLX1/VLX1P |
|||||
|
VLX2/VLX2P |
|||||
|
VLX3/VLX3P |
|||||
|
VLX4/VLX4P |
|||||
|
VLX5/VLX5P |
|||||
|
Custom PICV |
|||||
|
2FGB65B-EBV |
|||||
|
2FGB80B-EBV |
|||||
|
2FGB100B-EBV |
|||||
|
2FGB125B-EBV |
|||||
|
2FGB150B-EBV |
|||||
|
Reserved |
|||||
|
VLX2HF/VLX2PHF |
|||||
|
VLX3HF/VLX3PHF |
|||||
|
VLX4HF/VLX4PHF |
|||||
|
3 |
Present value |
Analog value |
VALVE STROKE (mm*100) |
Read only |
|
|
4 |
Present value |
Analog value |
OVER VOLTAGE EVENTS (24 v ac > 20%) (230 v > 10%) |
Read only |
|
|
5 |
Present value |
Analog value |
UNDER VOLTAGE EVENTS (v ac < 20%) (230 v < 10%) |
Read only |
|
|
6 |
Present value |
Analog value |
FULLY OPEN EVENTS |
Read only |
|
|
7 |
Present value |
Analog value |
FULLY OPEN EVENTS |
Read only |
|
|
8 |
Present value |
Analog value |
UNEXPECTED STALL CONDITION EVENTS (within calculated stroke) |
Read only |
|
|
9 |
Present value |
Analog value |
UNEXPECTED STALL CONDITION EVENTS (outside calculated stroke) |
Read only |
|
|
10 |
Present value |
Analog value |
VALVE STROKE ERROR > MAX (60 mm EBV/MVE-2-RS e 12 mm MVC-2-RS) |
Read only |
|
|
11 |
Present value |
Analog value |
VALVE STROKE ERROR < MIN (5 mm EBV/MVE-2-RS e 2 mm MVC-2-RS) |
Read only |
|
|
7 |
Present value |
Multi state value |
ACTUATOR OPERATING MODE: |
Read only |
|
|
Normal running |
|||||
|
Initial positioning |
|||||
|
Stroke calibration |
|||||
|
Fail safe |
|||||
|
Manual override |
|||||
|
4 |
Present value |
Binary value |
ACTUATOR OPERATING MODE (ERROR) |
Read only |
|
|
5 |
Present value |
Binary value (ERROR TYPE) |
TEMPERATURE SENSOR 1 ERROR |
Read only |
|
|
6 |
TEMPERATURE SENSOR 2 ERROR |
||||
|
20 |
PRESSURE SENSOR 1 ERROR |
||||
|
21 |
PRESSURE SENSOR 2 ERROR |
||||
|
7 |
CALIBRATED STROKE < MIN ERROR (5 mm for EBV/MVE-2-RS and 2 mm for MVC-2-RS) |
||||
|
8 |
CALIBRATED STROKE > MAX ERROR (60 mm for EBV/MVE-2-RS and 12 mm for MVC-2-RS) |
||||
|
9 |
UNEXPECTED STALL (INSIDE STROKE) ERROR |
||||
|
10 |
UNEXPECTED STALL (OUTSIDE STROKE) ERROR |
||||
|
11 |
UNDERVOLTAGE |
||||
|
12 |
OVERVOLTAGE |
||||
|
13 |
CLOCK ERROR |
||||
|
16 |
Present value |
Binary value |
COUNTERS RESET |
Read/write |
|
|
13 |
Present value |
Analog value |
FEEDBACK |
Read only |
|
|
14 |
Present value |
Analog value |
MAX. FLOW RATE |
Read/write |
|
|
15 |
Present value |
Analog value |
DESIGN FLOW RATE |
Read/write |
|
|
2 |
Present value |
Analog input |
INPUT PRESSURE VALUE |
Read only (available only for EBV and MVE-2-RS with Custom Energy Valve) |
|
|
3 |
Present value |
Analog input |
OUTPUT PRESSURE VALUE |
Read only (available only for EBV and MVE-2-RS with Custom Energy Valve) |
|
|
119 |
Present value |
Analog value |
DIFFERENTIAL PRESSURE |
Read only (available only for EBV and MVE-2-RS with Custom Energy Valve) |
|
|
16 |
Present value |
Analog value |
FLOW RATE SP X1 |
Read only |
|
|
17 |
Present value |
Analog value |
VALVE POSITION Y1 |
Read only |
|
|
18 |
Present value |
Analog value |
FLOW RATE SP X2 |
Read/write |
|
|
19 |
Present value |
Analog value |
VALVE POSITION Y2 |
Read/write |
|
|
20 |
Present value |
Analog value |
FLOW RATE SP X3 |
Read/write |
|
|
21 |
Present value |
Analog value |
VALVE POSITION Y3 |
Read/write |
|
|
22 |
Present value |
Analog value |
FLOW RATE SP X4 |
Read/write |
|
|
23 |
Present value |
Analog value |
VALVE POSITION Y4 |
Read/write |
|
|
24 |
Present value |
Analog value |
FLOW RATE SP X5 |
Read/write |
|
|
25 |
Present value |
Analog value |
VALVE POSITION Y5 |
Read/write |
|
|
26 |
Present value |
Analog value |
FLOW RATE SP X6 |
Read/write |
|
|
27 |
Present value |
Analog value |
VALVE POSITION Y6 |
Read/write |
|
|
28 |
Present value |
Analog value |
FLOW RATE SP X7 |
Read/write |
|
|
29 |
Present value |
Analog value |
VALVE POSITION Y7 |
Read/write |
|
|
30 |
Present value |
Analog value |
FLOW RATE SP X8 |
Read/write |
|
|
31 |
Present value |
Analog value |
VALVE POSITION Y8 |
Read/write |
|
|
32 |
Present value |
Analog value |
FLOW RATE SP X9 |
Read/write |
|
|
34 |
Present value |
Analog value |
FLOW RATE SP X10 |
Read only |
|
|
35 |
Present value |
Analog value |
VALVE POSITION Y10 |
Read only |
|
|
36 |
Present value |
Analog value |
INDICATED FLOW RATE |
Read/write |
|
|
37 |
Present value |
Analog value |
SETPOINT DELTA T CONTROL - HEATING |
Read/write |
|
|
38 |
Present value |
Analog value |
SETPOINT DELTA T CONTROL - COOLING |
Read/write |
|
|
39 |
Present value |
Analog value |
SETPOINT SUPPLY TEMPERATURE CONTROL - HEATING |
Read/write |
|
|
40 |
Present value |
Analog value |
SETPOINT SUPPLY TEMPERATURE CONTROL - COOLING |
Read/write |
|
|
41 |
Present value |
Analog value |
SETPOINT RETURN TEMPERATURE CONTROL - HEATING |
Read/write |
|
|
42 |
Present value |
Analog value |
SETPOINT RETURN TEMPERATURE CONTROL - COOLING |
Read/write |
|
|
43 |
Present value |
Analog value |
SETPOINT MIN. DELTA T HEATING |
Read/write |
|
|
44 |
Present value |
Analog value |
SETPOINT MIN. DELTA T COOLING |
Read/write |
|
|
45 |
Present value |
Analog value |
SETPOINT MAX. SUPPLY TEMPERATURE - HEATING |
Read/write |
|
|
46 |
Present value |
Analog value |
SETPOINT MIN. SUPPLY TEMPERATURE - COOLING |
Read/write |
|
|
47 |
Present value |
Analog value |
SETPOINT MAX. RETURN TEMPERATURE - HEATING |
Read/write |
|
|
48 |
Present value |
Analog value |
SETPOINT MIN. RETURN TEMPERATURE - COOLING |
Read/write |
|
|
49 |
Present value |
Analog value |
DESIGN POWER |
Read/write |
|
|
50 |
Present value |
Analog value |
SET MAX. POWER LIMIT |
Read/write |
|
|
0 |
Present value |
Analog input |
SUPPLY TEMPERATURE VALUE |
Read only if Binay Value 19 is 0 (Temperature Test Mode) |
|
|
1 |
Present value |
Analog input |
RETURN TEMPERATURE VALUE |
Read only if Binay Value 19 is 0 (Temperature Test Mode) |
|
|
51 |
Present value |
Analog value |
DELTA T VALUE (T1 – T2) |
Read only |
|
|
52 |
Present value |
Analog value |
INSTANT POWER |
Read only |
|
|
53 |
Present value |
Analog value |
HEATING ENERGY (LSR) |
Read only |
|
|
53 |
Present value |
Analog value |
HEATING ENERGY (MSR) |
Read only |
|
|
54 |
Present value |
Analog value |
COOLING ENERGY (LSR) |
Read only |
|
|
54 |
Present value |
Analog value |
COOLING ENERGY (MSR) |
Read only |
|
|
55 |
Present value |
Analog value |
HEATING ENERGY AT 31/12 (MSR) |
Read only |
|
|
56 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 1 |
Read only |
|
|
57 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 2 |
Read only |
|
|
58 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 3 |
Read only |
|
|
59 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 4 |
Read only |
|
|
60 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 5 |
Read only |
|
|
61 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 6 |
Read only |
|
|
62 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 7 |
Read only |
|
|
63 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 8 |
Read only |
|
|
64 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 9 |
Read only |
|
|
65 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 10 |
Read only |
|
|
66 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 11 |
Read only |
|
|
67 |
Present value |
Analog value |
HEATING ENERGY AT VALUE 12 |
Read only |
|
|
68 |
Present value |
Analog value |
COOLING ENERGY AT 31/12 (LSR) |
Read only |
|
|
68 |
Present value |
Analog value |
COOLING ENERGY AT 31/12 (MSR) |
Read only |
|
|
69 |
Present value |
Analog value |
COOLING ENERGY VALUE 1 |
Read only |
|
|
70 |
Present value |
Analog value |
COOLING ENERGY VALUE 2 |
Read only |
|
|
71 |
Present value |
Analog value |
COOLING ENERGY VALUE 3 |
Read only |
|
|
72 |
Present value |
Analog value |
COOLING ENERGY VALUE 4 |
Read only |
|
|
73 |
Present value |
Analog value |
COOLING ENERGY VALUE 5 |
Read only |
|
|
74 |
Present value |
Analog value |
COOLING ENERGY VALUE 6 |
Read only |
|
|
75 |
Present value |
Analog value |
COOLING ENERGY VALUE 7 |
Read only |
|
|
77 |
Present value |
Analog value |
COOLING ENERGY VALUE 9 |
Read only |
|
|
78 |
Present value |
Analog value |
COOLING ENERGY VALUE 10 |
Read only |
|
|
79 |
Present value |
Analog value |
COOLING ENERGY VALUE 11 |
Read only |
|
|
80 |
Present value |
Analog value |
COOLING ENERGY VALUE 12 |
Read only |
|
|
81 |
Present value |
Analog value |
CLOCK MINUTES |
Read/write |
|
|
1 |
Local time |
Device |
|||
|
82 |
Present value |
Analog value |
CLOCK HOURS |
Read/write |
|
|
1 |
Local time |
Device |
|||
|
83 |
Present value |
Analog value |
CLOCK DAY |
Read/write |
|
|
1 |
Local date |
Device |
|||
|
84 |
Present value |
Analog value |
CLOCK MONTH |
Read/write |
|
|
1 |
Local date |
Device |
|||
|
85 |
Present value |
Analog value |
CLOCK YEAR |
Read/write |
|
|
1 |
Local date |
Device |
|||
|
17 |
Present value |
Binary value |
FORCE FULLY CLOSE |
Read/write |
|
|
18 |
Present value |
Binary value |
FORCE FULLY OPEN |
Read/write |
|
|
19 |
Present value |
Binary value |
TEST TEMPERATURE MODE |
Read/write |
|
|
86 |
Present value |
Analog value |
MAX. POWER |
Read/write (read-only for EBV/MVC-2-RS) |
|
|
87 |
Present value |
Analog value |
MEDIA DENSITY |
Read/write |
|
|
88 |
Present value |
Analog value |
MEDIA SPECIFIC HEAT |
Read/write |
|
|
118 |
Present value |
Analog value |
DESIGN POWER DELTAT |
Read/write |
|
|
8 |
Present value |
Multi state value |
LOOP TYPE (P, P+I, P+I+D) |
Read/write |
|
|
89 |
Present value |
Analog value |
DERIVATIVE TIME (GAIN) |
Read/write |
|
|
90 |
Present value |
Analog value |
INTEGRAL TIME (MINUTES) |
Read/write |
|
|
91 |
Present value |
Analog value |
PROPORTIONAL BANDWIDTH (°C*10) |
Read/write |
|
|
92 |
Present value |
Analog value |
MONTH TIMESTAMP OF 31TH DECEMBER |
Read only |
|
|
93 |
Present value |
Analog value |
YEAR TIMESTAMP OF 31TH DECEMBER |
Read only |
|
|
94 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 1 |
Read only |
|
|
95 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 1 |
Read only |
|
|
96 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 2 |
Read only |
|
|
97 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 2 |
Read only |
|
|
98 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 3 |
Read only |
|
|
99 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 3 |
Read only |
|
|
100 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 4 |
Read only |
|
|
101 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 4 |
Read only |
|
|
102 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 5 |
Read only |
|
|
103 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 5 |
Read only |
|
|
104 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 6 |
Read only |
|
|
105 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 6 |
Read only |
|
|
106 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 7 |
Read only |
|
|
107 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 7 |
Read only |
|
|
108 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 8 |
Read only |
|
|
109 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 8 |
Read only |
|
|
110 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 9 |
Read only |
|
|
111 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 9 |
Read only |
|
|
112 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 10 |
Read only |
|
|
113 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 10 |
Read only |
|
|
114 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 11 |
Read only |
|
|
115 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 11 |
Read only |
|
|
116 |
Present value |
Analog value |
MONTH TIMESTAMP OF VALUE 12 |
Read only |
|
|
117 |
Present value |
Analog value |
YEAR TIMESTAMP OF VALUE 12 |
Read only |
|
List of BACnet object