Alarm Submenu Objects

Warning!

Please note that the following table contains objects for all series of the Control Point panels.

BACnet ID

Object property

Object name

Access

Description

AV40

Present value

ALARMS_NUMERIC1:Present Value

Read/write, memory

Current value of the parameter

AV40

Description

ALARMS_NUMERIC1:Name

Read/write, memory

User-defined name of the parameter

AV40

4206

ALARMS_NUMERIC1:Step

Read/write, memory

Step of the parameter value change. Default: 0.

AV40

Low limit

ALARMS_NUMERIC1:Low Limit

Read/write, memory

Minimum value of the parameter. Default: 0.

AV40

High limit

ALARMS_NUMERIC1:High Limit

Read/write, memory

Maximum value of the parameter. Default: 0.

AV40

4201

ALARMS_NUMERIC1:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

AV40

Out of service

ALARMS_NUMERIC1:Visibility

Read/write, memory

Activating display of the parameter in the submenu

AV40

4200

ALARMS_NUMERIC1:Editability

Read/write, memory

Enabling editability of the parameter

AV40

4202

ALARMS_NUMERIC1:Decimal Places

Read/write, memory

Number of displayed decimal places from 0 to 3

AV40

Units

ALARMS_NUMERIC1:Units

Read/write, memory

Supported units: ° C, ° F, Pa, Lx, ppm, m3/h, %RH, L/s, %, h

AV41

Present value

ALARMS_NUMERIC2:Present Value

Read/write, memory

Current value of the parameter

AV41

Description

ALARMS_NUMERIC2:Name

Read/write, memory

User-defined name of the parameter

AV41

4206

ALARMS_NUMERIC2:Step

Read/write, memory

Step of the parameter value change. Default: 0.

AV41

Low limit

ALARMS_NUMERIC2:Low Limit

Read/write, memory

Minimum value of the parameter. Default: 0.

AV41

High limit

ALARMS_NUMERIC2:High Limit

Read/write, memory

Maximum value of the parameter. Default: 0.

AV41

4201

ALARMS_NUMERIC2:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

AV41

Out of service

ALARMS_NUMERIC2:Visibility

Read/write, memory

Activating display of the parameter in the submenu

AV41

4200

ALARMS_NUMERIC2:Editability

Read/write, memory

Enabling editability of the parameter

AV41

4202

ALARMS_NUMERIC2:Decimal Places

Read/write, memory

Number of displayed decimal places from 0 to 3

AV41

Units

ALARMS_NUMERIC2:Units

Read/write, memory

Supported units: ° C, ° F, Pa, Lx, ppm, m3/h, %RH, L/s, %, h

AV42

Present value

ALARMS_NUMERIC3:Present Value

Read/write, memory

Current value of the parameter

AV42

Description

ALARMS_NUMERIC3:Name

Read/write, memory

User-defined name of the parameter

AV42

4206

ALARMS_NUMERIC3:Step

Read/write, memory

Step of the parameter value change. Default: 0.

AV42

Low limit

ALARMS_NUMERIC3:Low Limit

Read/write, memory

Minimum value of the parameter. Default: 0.

AV42

High limit

ALARMS_NUMERIC3:High Limit

Read/write, memory

Maximum value of the parameter. Default: 0.

AV42

4201

ALARMS_NUMERIC3:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

AV42

Out of service

ALARMS_NUMERIC3:Visibility

Read/write, memory

Activating display of the parameter in the submenu

AV42

4200

ALARMS_NUMERIC3:Editability

Read/write, memory

Enabling editability of the parameter

AV42

4202

ALARMS_NUMERIC3:Decimal Places

Read/write, memory

Number of displayed decimal places from 0 to 3

AV42

Units

ALARMS_NUMERIC3:Units

Read/write, memory

Supported units: ° C, ° F, Pa, Lx, ppm, m3/h, %RH, L/s, %, h

AV43

Present value

ALARMS_NUMERIC4:Present Value

Read/write, memory

Current value of the parameter

AV43

Description

ALARMS_NUMERIC4:Name

Read/write, memory

User-defined name of the parameter

AV43

4206

ALARMS_NUMERIC4:Step

Read/write, memory

Step of the parameter value change. Default: 0.

AV43

Low limit

ALARMS_NUMERIC4:Low Limit

Read/write, memory

Minimum value of the parameter. Default: 0.

AV43

High limit

ALARMS_NUMERIC4:High Limit

Read/write, memory

Maximum value of the parameter. Default: 0.

AV43

4201

ALARMS_NUMERIC4:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

AV43

Out of service

ALARMS_NUMERIC4:Visibility

Read/write, memory

Activating display of the parameter in the submenu

AV43

4200

ALARMS_NUMERIC4:Editability

Read/write, memory

Enabling editability of the parameter

AV43

4202

ALARMS_NUMERIC4:Decimal Places

Read/write, memory

Number of displayed decimal places from 0 to 3

AV43

Units

ALARMS_NUMERIC4:Units

Read/write, memory

Supported units: ° C, ° F, Pa, Lx, ppm, m3/h, %RH, L/s, %, h

AV44

Present value

ALARMS_NUMERIC5:Present Value

Read/write, memory

Current value of the parameter

AV44

Description

ALARMS_NUMERIC5:Name

Read/write, memory

User-defined name of the parameter

AV44

4206

ALARMS_NUMERIC5:Step

Read/write, memory

Step of the parameter value change. Default: 0.

AV44

Low limit

ALARMS_NUMERIC5:Low Limit

Read/write, memory

Minimum value of the parameter. Default: 0.

AV44

High limit

ALARMS_NUMERIC5:High Limit

Read/write, memory

Maximum value of the parameter. Default: 0.

AV44

4201

ALARMS_NUMERIC5:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

AV44

Out of service

ALARMS_NUMERIC5:Visibility

Read/write, memory

Activating display of the parameter in the submenu

AV44

4200

ALARMS_NUMERIC5:Editability

Read/write, memory

Enabling editability of the parameter

AV44

4202

ALARMS_NUMERIC5:Decimal Places

Read/write, memory

Number of displayed decimal places from 0 to 3

AV44

Units

ALARMS_NUMERIC5:Units

Read/write, memory

Supported units: ° C, ° F, Pa, Lx, ppm, m3/h, %RH, L/s, %, h

AV45

Present value

ALARMS_NUMERIC6:Present Value

Read/write, memory

Current value of the parameter

AV45

Description

ALARMS_NUMERIC6:Name

Read/write, memory

User-defined name of the parameter

AV45

4206

ALARMS_NUMERIC6:Step

Read/write, memory

Step of the parameter value change. Default: 0.

AV45

Low limit

ALARMS_NUMERIC6:Low Limit

Read/write, memory

Minimum value of the parameter. Default: 0.

AV45

High limit

ALARMS_NUMERIC6:High Limit

Read/write, memory

Maximum value of the parameter. Default: 0.

AV45

4201

ALARMS_NUMERIC6:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

AV45

Out of service

ALARMS_NUMERIC6:Visibility

Read/write, memory

Activating display of the parameter in the submenu

AV45

4200

ALARMS_NUMERIC6:Editability

Read/write, memory

Enabling editability of the parameter

AV45

4202

ALARMS_NUMERIC6:Decimal Places

Read/write, memory

Number of displayed decimal places from 0 to 3

AV45

Units

ALARMS_NUMERIC6:Units

Read/write, memory

Supported units: ° C, ° F, Pa, Lx, ppm, m3/h, %RH, L/s, %, h

AV46

Present value

ALARMSNUMERIC7:Present Value

Read/write, memory

Current value of the parameter

AV46

Description

ALARMS_NUMERIC7:Name

Read/write, memory

User-defined name of the parameter

AV46

4206

ALARMS_NUMERIC7:Step

Read/write, memory

Step of the parameter value change. Default: 0.

AV46

Low limit

ALARMS_NUMERIC7:Low Limit

Read/write, memory

Minimum value of the parameter. Default: 0.

AV46

High limit

ALARMS_NUMERIC7:High Limit

Read/write, memory

Maximum value of the parameter. Default: 0.

AV46

4201

ALARMS_NUMERIC7:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

AV46

Out of service

ALARMS_NUMERIC7:Visibility

Read/write, memory

Activating display of the parameter in the submenu

AV46

4200

ALARMS_NUMERIC7:Editability

Read/write, memory

Enabling editability of the parameter

AV46

4202

ALARMS_NUMERIC7:Decimal Places

Read/write, memory

Number of displayed decimal places from 0 to 3

AV46

Units

ALARMS_NUMERIC7:Units

Read/write, memory

Supported units: ° C, ° F, Pa, Lx, ppm, m3/h, %RH, L/s, %, h

AV47

Present value

ALARMS_NUMERIC8:Present Value

Read/write, memory

Current value of the parameter

AV47

Description

ALARMS_NUMERIC8:Name

Read/write, memory

User-defined name of the parameter

AV47

4206

ALARMS_NUMERIC8:Step

Read/write, memory

Step of the parameter value change. Default: 0.

AV47

Low limit

ALARMS_NUMERIC8:Low Limit

Read/write, memory

Minimum value of the parameter. Default: 0.

AV47

High limit

ALARMS_NUMERIC8:High Limit

Read/write, memory

Maximum value of the parameter. Default: 0.

AV47

4201

ALARMS_NUMERIC8:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

AV47

Out of service

ALARMS_NUMERIC8:Visibility

Read/write, memory

Activating display of the parameter in the submenu

AV47

4200

ALARMS_NUMERIC8:Editability

Read/write, memory

Enabling editability of the parameter

AV47

4202

ALARMS_NUMERIC8:Decimal Places

Read/write, memory

Number of displayed decimal places from 0 to 3

AV47

Units

ALARMS_NUMERIC8:Units

Read/write, memory

Supported units: ° C, ° F, Pa, Lx, ppm, m3/h, %RH, L/s, %, h

BV40

Present value

ALARMS_BOOLEAN1:Present Value

Read/write, memory

Current value of the parameter

BV40

Description

ALARMS_BOOLEAN1:Name

Read/write, memory

User-defined name of the parameter

BV40

4203

ALARMS_BOOLEAN1:True Text

Read/write, memory

Text for the parameter’s true value

BV40

4204

ALARMS_BOOLEAN1:False Text

Read/write, memory

Text for the parameter’s false value

BV40

4201

ALARMS_BOOLEAN1:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

BV40

Out of service

ALARMS_BOOLEAN1:Visibility

Read/write, memory

Activating the display of the parameter in the submenu

BV40

4200

ALARMS_BOOLEAN1:Editability

Read/write, memory

Enabling editability of the parameter

BV41

Present value

ALARMS_BOOLEAN2:Present Value

Read/write, memory

Current value of the parameter

BV41

Description

ALARMS_BOOLEAN2:Name

Read/write, memory

User-defined name of the parameter

BV41

4203

ALARMS_BOOLEAN2:True Text

Read/write, memory

Text for the parameter’s true value

BV41

4204

ALARMS_BOOLEAN2:False Text

Read/write, memory

Text for the parameter’s false value

BV41

4201

ALARMS_BOOLEAN2:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

BV41

Out of service

ALARMS_BOOLEAN2:Visibility

Read/write, memory

Activating the display of the parameter in the submenu

BV41

4200

ALARMS_BOOLEAN2:Editability

Read/write, memory

Enabling editability of the parameter

BV42

Present value

ALARMS_BOOLEAN3:Present Value

Read/write, memory

Current value of the parameter

BV42

Description

ALARMS_BOOLEAN3:Name

Read/write, memory

User-defined name of the parameter

BV42

4203

ALARMS_BOOLEAN3:True Text

Read/write, memory

Text for the parameter’s true value

BV42

4204

ALARMS_BOOLEAN3:False Text

Read/write, memory

Text for the parameter’s false value

BV42

4201

ALARMS_BOOLEAN3:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

BV42

Out of service

ALARMS_BOOLEAN3:Visibility

Read/write, memory

Activating the display of the parameter in the submenu

BV42

4200

ALARMS_BOOLEAN3:Editability

Read/write, memory

Enabling editability of the parameter

BV43

Present value

ALARMS_BOOLEAN4:Present Value

Read/write, memory

Current value of the parameter

BV43

Description

ALARMS_BOOLEAN4:Name

Read/write, memory

User-defined name of the parameter

BV43

4203

ALARMS_BOOLEAN4:True Text

Read/write, memory

Text for the parameter’s true value

BV43

4204

ALARMS_BOOLEAN4:False Text

Read/write, memory

Text for the parameter’s false value

BV43

4201

ALARMS_BOOLEAN4:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

BV43

Out of service

ALARMS_BOOLEAN4:Visibility

Read/write, memory

Activating the display of the parameter in the submenu

BV43

4200

ALARMS_BOOLEAN4:Editability

Read/write, memory

Enabling editability of the parameter

BV44

Present value

ALARMS_BOOLEAN5:Present Value

Read/write, memory

Current value of the parameter

BV44

Description

ALARMS_BOOLEAN5:Name

Read/write, memory

User-defined name of the parameter

BV44

4203

ALARMS_BOOLEAN5:True Text

Read/write, memory

Text for the parameter’s true value

BV44

4204

ALARMS_BOOLEAN5:False Text

Read/write, memory

Text for the parameter’s false value

BV44

4201

ALARMS_BOOLEAN5:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

BV44

Out of service

ALARMS_BOOLEAN5:Visibility

Read/write, memory

Activating the display of the parameter in the submenu

BV44

4200

ALARMS_BOOLEAN5:Editability

Read/write, memory

Enabling editability of the parameter

BV45

Present value

ALARMS_BOOLEAN6:Present Value

Read/write, memory

Current value of the parameter

BV45

Description

ALARMS_BOOLEAN6:Name

Read/write, memory

User-defined name of the parameter

BV45

4203

ALARMS_BOOLEAN6:True Text

Read/write, memory

Text for the parameter’s true value

BV45

4204

ALARMS_BOOLEAN6:False Text

Read/write, memory

Text for the parameter’s false value

BV45

4201

ALARMS_BOOLEAN6:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

BV45

Out of service

ALARMS_BOOLEAN6:Visibility

Read/write, memory

Activating the display of the parameter in the submenu

BV45

4200

ALARMS_BOOLEAN6:Editability

Read/write, memory

Enabling editability of the parameter

BV46

Present value

ALARMS_BOOLEAN7:Present Value

Read/write, memory

Current value of the parameter

BV46

Description

ALARMS_BOOLEAN7:Name

Read/write, memory

User-defined name of the parameter

BV46

4203

ALARMS_BOOLEAN7:True Text

Read/write, memory

Text for the parameter’s true value

BV46

4204

ALARMS_BOOLEAN7:False Text

Read/write, memory

Text for the parameter’s false value

BV46

4201

ALARMS_BOOLEAN7:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

BV46

Out of service

ALARMS_BOOLEAN7:Visibility

Read/write, memory

Activating the display of the parameter in the submenu

BV46

4200

ALARMS_BOOLEAN7:Editability

Read/write, memory

Enabling editability of the parameter

BV47

Present value

ALARMS_BOOLEAN8:Present Value

Read/write, memory

Current value of the parameter

BV47

Description

ALARMS_BOOLEAN8:Name

Read/write, memory

User-defined name of the parameter

BV47

4203

ALARMS_BOOLEAN8:True Text

Read/write, memory

Text for the parameter’s true value

BV47

4204

ALARMS_BOOLEAN8:False Text

Read/write, memory

Text for the parameter’s false value

BV47

4201

ALARMS_BOOLEAN8:Priority

Read/write, memory

Priority of the parameter for sequence of display in the submenu

BV47

Out of service

ALARMS_BOOLEAN8:Visibility

Read/write, memory

Activating the display of the parameter in the submenu

BV47

4200

ALARMS_BOOLEAN8:Editability

Read/write, memory

Enabling editability of the parameter