40083

82

0x52

BLINDNUMERIC1

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

40960

959

0x3BF

BLIND_MENU

ACTIVE_POINTS

Read/write

Memory

Number of active parameters in the submenu.

40963

962

0x3C2

BLINDNUMERIC1

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


40965

964

0x3C4

BLINDNUMERIC1

STEP

Read/write

Memory

Step of the parameter value change.

The default value is 0.

40966

965

0x3C5

BLINDNUMERIC1

LOW_LIMIT

Read/write

Memory

Minimum value of the parameter.

The default value is 0.

40967

966

0x3C6

BLINDNUMERIC1

HIGH_LIMIT

Read/write

Memory

Maximum value of the parameter.

The default value is 0.

40968

967

0x3C7

BLINDNUMERIC1

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

40969

968

0x3C8

BLINDNUMERIC1

CONFIGURATION

Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active(def)

2

FirstPointActive

Not decimal(def)

Decimal(def)

3

SecondPointActive

Not decimal(def)

Decimal(def)

4

ThirdPointActive

Not decimal(def)

Decimal(def)

6

C unit active

not_visible(def)

visible

7

F unit active

not_visible(def)

visible

8

Pa unit active

not_visible(def)

visible

9

Lx unit active

not_visible(def)

visible

10

ppm unit active

not_visible(def)

visible

11

m3/h unit active

not_visible(def)

visible

12

%Rh unit active

not_visible(def)

visible

13

l/s unit active

not_visible(def)

visible

14

% unit active

not_visible(def)

visible

15

h unit active

not_visible(def)

visible

40084

83

0x53

BLINDNUMERIC2

 PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

40972

971

0x3CB

BLINDNUMERIC2

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.

Default name: Num2

40974

973

0x3CD

BLINDNUMERIC2

STEP

Read/write

Memory

Step of the parameter value change.

The default value is 0.

40975

974

0x3CE

BLINDNUMERIC2

LOW_LIMIT

Read/write

Memory

Minimum value of the parameter.

The default value is 0.

40976

975

0x3CF

BLINDNUMERIC2

HIGH_LIMIT

Read/write

Memory

Maximum value of the parameter.

The default value is 0.

40977

976

0x3D0

BLINDNUMERIC2

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

40978

977

0x3D1

BLINDNUMERIC2

CONFIGURATION

Read/write

Memory

See the table in BlindNumeric1Configuration(40510)

40085

84

0x54

BLINDNUMERIC3

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

40981

980

0x3D4

BLINDNUMERIC3

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.

Default name: Num2

40983

982

0x3D6

BLINDNUMERIC3

STEP

Read/write

Memory

Step of the parameter value change.

The default value is 0.

40984

983

0x3D7

BLINDNUMERIC3

LOW_LIMIT

Read/write

Memory

Minimum value of the parameter.

The default value is 0.

40985

984

0x3D8

BLINDNUMERIC3

HIGH_LIMIT

Read/write

Memory

Maximum value of the parameter.

The default value is 0.

40986

985

0x3D9

BLINDNUMERIC3

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

40987

986

0x3DA

BLINDNUMERIC3

CONFIGURATION

Read/write

Memory

See the table in BlindNumeric1Configuration(40510)

40086

85

0x55

BLINDNUMERIC4

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

40990

989

0x3DD

BLINDNUMERIC4

NAME (32–bits)

Read/write

Memory

Displaying user defined parameter name.

Default name: Num2

40992

991

0x3DF

BLINDNUMERIC4

STEP

Read/write

Memory

Step of the parameter value change.

The default value is 0.

40993

992

0x3E0

BLINDNUMERIC4

LOW_LIMIT

Read/write

Memory

Minimum value of the parameter.

The default value is 0.

40994

993

0x3E1

BLINDNUMERIC4

HIGH_LIMIT

Read/write

Memory

Maximum value of the parameter.

The default value is 0.

40995

994

0x3E2

BLINDNUMERIC4

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

40996

995

0x3E3

BLINDNUMERIC4

CONFIGURATION

Read/write

Memory

See the table in BlindNumeric1Configuration(40510)

40087

86

0x56

BLINDNUMERIC5

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

40999

998

0x3E6

BLINDNUMERIC5

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.

Default name: Num2

41001

1000

0x3E8

BLINDNUMERIC5

STEP

Read/write

Memory

Step of the parameter value change.

The default value is 0.

41002

1001

0x3E9

BLINDNUMERIC5

LOW_LIMIT

Read/write

Memory

Minimum value of the parameter.

The default value is 0.

41003

1002

0x3EA

BLINDNUMERIC5

HIGH_LIMIT

Read/write

Memory

Maximum value of the parameter.

The default value is 0.

41004

1003

0x3EB

BLINDNUMERIC5

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41005

1004

0x3EC

BLINDNUMERIC5

CONFIGURATION

Read/write

Memory

See the table in BlindNumeric1Configuration(40510)

40088

87

0x57

BLINDNUMERIC6

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41008

1007

0x3EF

BLINDNUMERIC6

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.

Default name: Num2

41010

1009

0x3F1

BLINDNUMERIC6

STEP

Read/write

Memory

Step of the parameter value change.

The default value is 0.

41011

1010

0x3F2

BLINDNUMERIC6

LOW_LIMIT

Read/write

Memory

Minimum value of the parameter.

The default value is 0.

41012

1011

0x3F3

BLINDNUMERIC6

HIGH_LIMIT

Read/write

Memory

Maximum value of the parameter.

The default value is 0.

41013

1012

0x3F4

BLINDNUMERIC6

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41014

1013

0x3F5

BLINDNUMERIC6

CONFIGURATION

Read/write

Memory

See the table in BlindNumeric1Configuration(40510)

40089

88

0x58

BLINDNUMERIC7

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41017

1016

0x3F8

BLINDNUMERIC7

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.

Default name: Num2

41019

1018

0x3FA

BLINDNUMERIC7

STEP

Read/write

Memory

Step of the parameter value change.

The default value is 0.

41020

1019

0x3FB

BLINDNUMERIC7

LOW_LIMIT

Read/write

Memory

Minimum value of the parameter.

The default value is 0.

41021

1020

0x3FC

BLINDNUMERIC7

HIGH_LIMIT

Read/write

Memory

Maximum value of the parameter.

The default value is 0.

41022

1021

0x3FD

BLINDNUMERIC7

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41023

1022

0x3FE

BLINDNUMERIC7

CONFIGURATION

Read/write

Memory

See the table in BlindNumeric1Configuration(40510)

40090

89

0x59

BLINDNUMERIC8

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41026

1025

0x401

BLINDNUMERIC8

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.

Default name: Num2

41028

1027

0x403

BLINDNUMERIC8

STEP

Read/write

Memory

Step of the parameter value change.

The default value is 0.

41029

1028

0x404

BLINDNUMERIC8

LOW_LIMIT

Read/write

Memory

Minimum value of the parameter.

The default value is 0.

41030

1029

0x405

BLINDNUMERIC8

HIGH_LIMIT

Read/write

Memory

Maximum value of the parameter.

The default value is 0.

41031

1030

0x406

BLINDNUMERIC8

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41032

1031

0x407

BLINDNUMERIC8

CONFIGURATION

Read/write

Memory

See the table in BlindNumeric1Configuration(40510)

40111

110

0x6E

BLIND_BOOLEAN_ALL

PRESENT_VALUES

Read/write

Memory

See the table in 30107 register

40146

145

0x91

BLINDBOOLEAN1

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41035

1034

0x40A

BLINDBOOLEAN1

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


41037

1036

0x40C

BLINDBOOLEAN1

TRUETEXT (32–bits)

Read/write

Memory

Text for parameter  “true” state value.


41039

1038

0x40E

BLINDBOOLEAN1

FALSETEXT (32–bits)

Read/write

Memory

Text for parameter  “false” state value.


41041

1040

0x410

BLINDBOOLEAN1

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in Submenu

41042

1041

0x411

BLINDBOOLEAN1

CONFIGURATION

Re Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active

1

Editable

Not editable

Editable(def)

40147

146

0x92

BLINDBOOLEAN2

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41045

1044

0x414

BLINDBOOLEAN2

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


41047

1046

0x416

BLINDBOOLEAN2

TRUETEXT (32–bits)

Read/write

Memory

Text for the parameter’s true value.


41049

1048

0x418

BLINDBOOLEAN2

FALSETEXT (32–bits)

Read/write

Memory

Text for the parameter‘s false value.


41051

1050

0x41A

BLINDBOOLEAN2

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41052

1051

0x41B

BLINDBOOLEAN2

CONFIGURATION

Re Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active

1

Editable

Not editable

Editable(def)

40148

147

0x93

BLINDBOOLEAN3

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41055

1054

0x41E

BLINDBOOLEAN3

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


41057

1056

0x420

BLINDBOOLEAN3

TRUETEXT (32–bits)

Read/write

Memory

Text for the parameter’s true value.


41059

1058

0x422

BLINDBOOLEAN3

FALSETEXT (32–bits)

Read/write

Memory

Text for the parameter‘s false value.


41061

1060

0x424

BLINDBOOLEAN3

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41062

1061

0x425

BLINDBOOLEAN3

CONFIGURATION

Re Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active

1

Editable

Not editable

Editable(def)

40149

148

0x94

BLINDBOOLEAN4

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41065

1064

0x428

BLINDBOOLEAN4

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


41067

1066

0x42A

BLINDBOOLEAN4

TRUETEXT (32–bits)

Read/write

Memory

Text for the parameter’s true value.


41069

1068

0x42C

BLINDBOOLEAN4

FALSETEXT (32–bits)

Read/write

Memory

Text for the parameter‘s false value.


41071

1070

0x42E

BLINDBOOLEAN4

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41072

1071

0x42F

BLINDBOOLEAN4

CONFIGURATION

Re Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active

1

Editable

Not editable

Editable(def)

40150

149

0x95

BLINDBOOLEAN5

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41075

1074

0x432

BLINDBOOLEAN5

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


41077

1076

0x434

BLINDBOOLEAN5

TRUETEXT (32–bits)

Read/write

Memory

Text for the parameter’s true value.


41079

1078

0x436

BLINDBOOLEAN5

FALSETEXT (32–bits)

Read/write

Memory

Text for the parameter‘s false value.


41081

1080

0x438

BLINDBOOLEAN5

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41082

1081

0x439

BLINDBOOLEAN5

CONFIGURATION

Re Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active

1

Editable

Not editable

Editable(def)

40151

150

0x96

BLINDBOOLEAN6

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41085

1084

0x43E

BLINDBOOLEAN6

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


41087

1086

0x440

BLINDBOOLEAN6

TRUETEXT (32–bits)

Read/write

Memory

Text for the parameter’s true value.


41089

1088

0x442

BLINDBOOLEAN6

FALSETEXT (32–bits)

Read/write

Memory

Text for the parameter‘s false value.


41091

1090

0x444

BLINDBOOLEAN6

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41092

1091

0x445

BLINDBOOLEAN6

CONFIGURATION

Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active

1

Editable

Not editable

Editable(def)

40152

151

0x97

BLINDBOOLEAN7

 PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41095

1094

0x446

BLINDBOOLEAN7

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


41097

1096

0x448

BLINDBOOLEAN7

TRUETEXT (32–bits)

Read/write

Memory

Text for the parameter’s true value.


41099

1098

0x44A

BLINDBOOLEAN7

FALSETEXT (32–bits)

Read/write

Memory

Text for the parameter‘s false value.


41101

1100

0x44C

BLINDBOOLEAN7

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41102

1101

0x44D

BLINDBOOLEAN7

CONFIGURATION

Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active

1

Editable

Not editable

Editable(def)

40153

152

0x98

BLINDBOOLEAN8

PRESENT_VALUE

Read/write

Memory

Present value of the parameter.

41105

1104

0x450

BLINDBOOLEAN8

NAME (32–bits)

Read/write

Memory

Displaying user-defined parameter name.


41107

1106

0x452

BLINDBOOLEAN8

TRUETEXT (32–bits)

Read/write

Memory

Text for the parameter’s true value.


41109

1108

0x454

BLINDBOOLEAN8

FALSETEXT (32–bits)

Read/write

Memory

Text for the parameter‘s false value.


41111

1110

0x456

BLINDBOOLEAN8

PRIORITY

Read/write

Memory

Priority of the parameter for sequence of display in  the submenu.

41112

1111

0x457

BLINDBOOLEAN8

CONFIGURATION

Read/write

Memory

Bit

Name

0

1

0

Active

Not active(def)

Active

1

Editable

Not editable

Editable(def)